{"id":1935,"date":"2026-06-23T09:08:01","date_gmt":"2026-06-23T09:08:01","guid":{"rendered":"https:\/\/maydomau.vn\/may-do-mau-quang-pho-konica-minolta-cf-300\/"},"modified":"2026-06-23T09:26:07","modified_gmt":"2026-06-23T09:26:07","slug":"konica-minolta-cf-300-spectrophotometer","status":"publish","type":"product","link":"https:\/\/maydomau.vn\/en\/san-pham\/konica-minolta-cf-300-spectrophotometer\/","title":{"rendered":"Konica Minolta CF-300 Spectrophotometer"},"content":{"rendered":"<h2 id=\"mts-thong-tin-may-do-mau-quang-pho-konica-minolta-cf-300\">Introduction to Konica Minolta CF-300 Spectrophotometer<\/h2>\n<p>The <strong>Konica Minolta CF-300<\/strong> Spectrophotometer is a high-speed and high-precision spectrophotometer capable of measuring small target areas. It features non-contact measurement technology, making it suitable for measuring fragile or easily stained objects. The CF-300 is engineered to enhance quality control efficiency through high-speed, non-contact measurements directly on production lines.<\/p>\n<p><a href=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa1.jpg\"><img decoding=\"async\" class=\"aligncenter wp-image-1931 size-full\" src=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa1.jpg\" alt=\"\" width=\"1300\" height=\"1300\" title=\"\" srcset=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa1.jpg 1300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa1-300x300.jpg 300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa1-1024x1024.jpg 1024w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa1-150x150.jpg 150w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa1-768x768.jpg 768w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa1-510x510.jpg 510w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa1-100x100.jpg 100w\" sizes=\"(max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<h2 id=\"mts-dac-trung-cua-may-do-mau-quang-pho-konica-minolta-cf-300\" class=\"ftwp-heading\">Key Features of Konica Minolta CF-300 Spectrophotometer<\/h2>\n<p>Konica Minolta CF-300:<\/p>\n<ul>\n<li>Capable of measuring small target areas<\/li>\n<li>Non-contact measurement<\/li>\n<li>High-speed measurement<\/li>\n<\/ul>\n<p><strong>Example Configuration:<\/strong><br \/>\nThe CF-300 can be utilized with the following configurations:<\/p>\n<ul>\n<li>Desktop stand<\/li>\n<li>Bottom port stand (sold separately)<\/li>\n<li>Zero Calibration Box (L: 60 mm)<\/li>\n<li>CF-A37 Camera Adapter<\/li>\n<li>Color panel (14 colors)<\/li>\n<\/ul>\n<p><strong>Optional Accessories:<\/strong><\/p>\n<ul>\n<li>\n<ul>\n<li>CF-A32 1.3MP USB Camera Kit<\/li>\n<li>Lens for USB Camera CS-to-C-Mount 1.3MP USB Camera CF-A30<\/li>\n<li>CF-A29 Adapter Advertisements<\/li>\n<li>AC-A308 AC Power Adapter<\/li>\n<li>IF-A39 USB Cable (2m) for USB Camera<\/li>\n<li>CF-A24 White Calibration Plate<\/li>\n<li>CF-A25 Accessory Case<\/li>\n<li>Screws for securing the target mask<\/li>\n<li>CF-A23 Target Mask Adapter for white calibration<\/li>\n<li>CF-A38 Glass Target Mask (Non-contact)<\/li>\n<li>CF-A26 Adapter for Desktop Stand<\/li>\n<li>IF-A36 RS-232C Cable (2 m)<\/li>\n<li>PC (commercially available)<\/li>\n<li>SpectraMagic DX Color Data Software (Optional)<\/li>\n<li>SpectraMagic DX Professional Edition Color Data Software (Version 1.2 or later)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><strong>System Requirements:<\/strong><br \/>\nSpectraMagic DX color data software requires the following system specifications:<\/p>\n<p>Advertisements<\/p>\n<ul>\n<li>\n<ul>\n<li><strong>Operating System:<\/strong> Windows (Version 1.2 or later)<\/li>\n<li><strong>Processor:<\/strong> Intel Core i5 or equivalent<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><strong>Memory:<\/strong> At least 4 GB RAM<\/li>\n<li><strong>Hard Drive:<\/strong> At least 10 GB of free disk space<\/li>\n<li><strong>Display:<\/strong> Hardware capable of displaying 1,280 x 768 pixels \/ 16-bit color or higher<\/li>\n<li><strong>Other:<\/strong> A USB port or serial port is required for connection to the instrument. A USB port is required for the protection key if utilized.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><a href=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa12.jpg\"><img decoding=\"async\" class=\"aligncenter wp-image-1929 size-full\" src=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa12.jpg\" alt=\"\" width=\"1300\" height=\"1300\" title=\"\" srcset=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa12.jpg 1300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa12-300x300.jpg 300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa12-1024x1024.jpg 1024w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa12-150x150.jpg 150w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa12-768x768.jpg 768w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa12-510x510.jpg 510w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/caa12-100x100.jpg 100w\" sizes=\"(max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<h2 id=\"mts-huong-dan-su-dung-may-do-mau-quang-pho-konica-minolta-cf-300\" class=\"ftwp-heading\"><strong>User Guide for Konica Minolta CF-300 Spectrophotometer<\/strong><\/h2>\n<p><strong>Measuring Small Target Areas:<\/strong><br \/>\nThe CF-300 is capable of measuring the color of small target areas such as watch faces and straps, smartphone components, eyeglass frames, fasteners, buttons, fountain pens, etc. To measure a small target area, follow these steps:<\/p>\n<ol>\n<li>Ensure that the spectrophotometer is properly installed on a stable surface.<\/li>\n<li>Turn on the spectrophotometer and allow it to initialize.<\/li>\n<li>Position the small target area in front of the spectrophotometer.<\/li>\n<li>Adjust the distance between the target area and the spectrophotometer to approximately 1 mm.<\/li>\n<li>Initiate the measurement process using the software or controller provided with the spectrophotometer.<\/li>\n<li>Record or analyze the measurement data as required.<\/li>\n<\/ol>\n<p><strong>Non-Contact Measurement:<\/strong><br \/>\nThe CF-300 utilizes an integrating sphere that enables color measurements at a distance of 1 mm from the target object. This non-contact measurement feature is highly useful when measuring the color of cosmetics like lipstick, foundation, wet paint, or other targets that could stain the instrument during contact measurement. To perform a non-contact measurement, follow these steps:<\/p>\n<ol start=\"7\">\n<li>Ensure that the spectrophotometer is properly installed on a stable surface.<\/li>\n<li>Turn on the spectrophotometer and allow it to initialize.<\/li>\n<li>Position the target object in front of the spectrophotometer.<\/li>\n<li>Adjust the distance between the target object and the spectrophotometer to approximately 1 mm.<\/li>\n<li>Initiate the measurement process using the software or controller provided with the spectrophotometer.<\/li>\n<\/ol>\n<ul>\n<li>\n<ul>\n<li>\n<ol>\n<li><\/li>\n<\/ol>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><strong>High-Speed Measurement:<\/strong><br \/>\nThe CF-300 features high-speed measurement capability, requiring only about 0.1 seconds per measurement. It can also perform continuous measurements at a minimum interval of approximately 0.2 seconds, allowing up to 5 measurements per second. To perform high-speed measurements, follow these steps:<\/p>\n<ol>\n<li>\n<ol>\n<li>Ensure that the spectrophotometer is properly installed on a stable surface.<\/li>\n<li>Turn on the spectrophotometer and allow it to initialize.<\/li>\n<li>Position the target object in front of the spectrophotometer.<\/li>\n<li>Initiate the measurement process using the software or controller provided with the spectrophotometer.<\/li>\n<li>Record or analyze the measurement data as required.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<p><strong>Capability to Measure Small Target Areas<\/strong><\/p>\n<ol start=\"2\">\n<li>\n<ul>\n<li>Capable of measuring targets as small as 0.75\u00d71 mm, the CF-300 can be used to measure the color of watch screws, micro smartphone parts, gaming console components, etc.<\/li>\n<li>The view finder cursor makes it easy to pinpoint the measurement area, effectively reducing the likelihood of alignment errors.\n<ul>\n<li>Measures the color of small target zones such as watch dials and straps, smartphone components, spectacle frames, fasteners, buttons, fountain pens, etc.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<p><strong>Non-Contact Measurement<\/strong><\/p>\n<ul>\n<li>The CF-300 utilizes an integrating sphere that enables color measurements at a distance of 1 mm from the target object.<\/li>\n<li>Sphere-based optical geometry measurements ensure that the CF-300 data is compatible with conventional contact spectrophotometers.\n<ul>\n<li>Measures the color of cosmetics like lipstick or foundation, liquid paints, or other targets that might contaminate the instrument during contact measurement.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><strong>High-Speed Measurement<\/strong><\/p>\n<ul>\n<li>Requiring only about 0.1 seconds per reading and capable of continuous scanning at a minimum interval of approximately 0.2 seconds, the CF-300 can perform up to 5 measurements per second*.<\/li>\n<li>For integration into high-speed production line scanning, the software must be customized according to the customer&#8217;s communication protocols.<\/li>\n<\/ul>\n<ul>\n<li>Enhancing quality control efficiency through high-speed, non-contact measurements on the production line.<\/li>\n<\/ul>\n<h4><span id=\"specifications\">Technical Specifications of Konica Minolta CF-300 Spectrophotometer<\/span><\/h4>\n<table width=\"1234\">\n<tbody>\n<tr>\n<td width=\"53\"><\/td>\n<td colspan=\"7\" width=\"318\">CF-300 Spectrophotometer<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"53\">Illumination\/viewing system<\/td>\n<td colspan=\"7\" width=\"318\">di:8\u00b0, de:8\u00b0 (diffuse illumination: 8\u00b0 viewing)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"318\">SCI (Specular Component Included) \/ SCE (Specular Component Excluded) switchable<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"318\">Complies with JIS Z 8722 condition c, ISO 7724\/1 standards<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Integrating sphere size<\/td>\n<td colspan=\"7\" width=\"318\">\u00d8152 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Detector<\/td>\n<td colspan=\"7\" width=\"318\">Dual 40-element silicon photodiode array<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Spectral separation device<\/td>\n<td colspan=\"7\" width=\"318\">Planar diffraction grating<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Wavelength range<\/td>\n<td colspan=\"7\" width=\"318\">400 to 700 nm<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Wavelength pitch<\/td>\n<td colspan=\"7\" width=\"318\">10 nm<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Measurement range<\/td>\n<td colspan=\"7\" width=\"318\">0 to 175%; Output\/display resolution: 0.01%<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Light source<\/td>\n<td colspan=\"7\" width=\"318\">High CRI white LEDs<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Illumination area<\/td>\n<td rowspan=\"2\" width=\"30\">MAV<\/td>\n<td width=\"51\">\u00d811 mm<\/td>\n<td rowspan=\"2\" width=\"34\">XUSAV<\/td>\n<td width=\"57\">5\u00d77 mm<\/td>\n<td rowspan=\"2\" width=\"49\">NC\/NC with glass (Non-contact measurement)<\/td>\n<td colspan=\"2\" width=\"97\">\u00d834 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Measurement area<\/td>\n<td width=\"51\">\u00d88 mm<\/td>\n<td width=\"57\">0.75\u00d71 mm<\/td>\n<td width=\"48\">\u00d88 mm<\/td>\n<td width=\"48\">0.75\u00d71 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Measurement distance<\/td>\n<td colspan=\"7\" width=\"318\">\n<ul>\n<li>Contact measurement (MAV\/XUSAV target mask): 0.0 mm \/ Non-contact measurement (NC target mask): 1.0 mm<\/li>\n<li>Non-contact measurement (NC target mask with glass): 0.7 mm<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Measurement time<\/td>\n<td colspan=\"7\" width=\"318\">Approx. 0.1 second<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Minimum measurement interval<\/td>\n<td colspan=\"7\" width=\"318\">Approx. 0.2 second<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Repeatability<\/td>\n<td colspan=\"7\" width=\"318\">\n<ul>\n<li><strong>Colorimetric value:<\/strong> Standard deviation within \u0394E*ab 0.02<\/li>\n<li>(When MAV\/SCI contact measurements of the white calibration plate are performed 30 times at 1-second intervals after white calibration)<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Inter-instrument agreement<\/td>\n<td colspan=\"7\" width=\"318\">Within \u0394E*ab 0.15 (Based on MAV\/SCI contact measurements of 12 BCRA Series II color tiles compared to values measured with the master body under Konica Minolta standard conditions)<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Interface<\/td>\n<td colspan=\"7\" width=\"318\">USB 2.0, RS-232C<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Power<\/td>\n<td colspan=\"7\" width=\"318\">Dedicated AC adapter (AC 100 to 240 V, 50\/60 Hz)<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Operating temperature\/humidity range<\/td>\n<td colspan=\"7\" width=\"318\">15 to 30\u00b0C, relative humidity 80% or less (at 30\u00b0C) non-condensing<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Storage temperature\/humidity range<\/td>\n<td colspan=\"7\" width=\"318\">0 to 40\u00b0C, relative humidity 80% or less (at 35\u00b0C) non-condensing<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Dimensions (W \u00d7 H \u00d7 D)<\/td>\n<td colspan=\"7\" width=\"318\"><strong>Approx. 186 \u00d7 202 \u00d7 317 mm (Including handle height<\/strong>: 246 mm)<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Weight<\/td>\n<td colspan=\"7\" width=\"318\">Approx. 7.3 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"53\">Measurement items*<\/td>\n<td colspan=\"7\" width=\"318\">Various color spaces, indices, and color difference formulas are displayed within the software windows of the separately sold SpectraMagic DX color management software.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Introduction to Konica Minolta CF-300 Spectrophotometer The Konica Minolta CF-300 Spectrophotometer is a high-speed and high-precision spectrophotometer capable of measuring small target areas. It features non-contact measurement technology, making it suitable for measuring fragile or easily stained objects. The CF-300 is engineered to enhance quality control efficiency through high-speed, non-contact measurements directly on production lines.<\/p>\n","protected":false},"featured_media":1934,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[108],"product_cat":[69],"product_tag":[1306,1305,1302,1303,1304,1307],"class_list":["post-1935","product","type-product","status-publish","has-post-thumbnail","product_brand-konica","product_cat-spectrophotometer","product_tag-continuous-surface-spectral-analysis","product_tag-in-line-color-quality-control-system","product_tag-industrial-color-spectrophotometer","product_tag-konica-minolta-cf-300","product_tag-non-contact-color-measurement-device","product_tag-photometric-color-assessment-instrument","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product\/1935","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/comments?post=1935"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/media\/1934"}],"wp:attachment":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/media?parent=1935"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_brand?post=1935"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_cat?post=1935"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_tag?post=1935"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}