{"id":2141,"date":"2026-06-25T09:31:21","date_gmt":"2026-06-25T09:31:21","guid":{"rendered":"https:\/\/maydomau.vn\/may-do-mau-sac-va-do-bong-quang-pho-kieu-doc-konica-minolta-cm-36dgv\/"},"modified":"2026-06-25T09:43:42","modified_gmt":"2026-06-25T09:43:42","slug":"konica-minolta-cm-36dgv-vertical-spectrophotometer-and-gloss-meter","status":"publish","type":"product","link":"https:\/\/maydomau.vn\/en\/san-pham\/konica-minolta-cm-36dgv-vertical-spectrophotometer-and-gloss-meter\/","title":{"rendered":"Konica Minolta CM-36dGV Vertical Spectrophotometer and Gloss Meter"},"content":{"rendered":"<h2 id=\"mts-gioi-thieu-may-do-mau-sac-va-do-bong-quang-pho-kieu-doc-konica-minolta-cm-36dgv\" class=\"ftwp-heading\">Introduction to KONICA MINOLTA CM-36dGV Vertical Spectrophotometer<\/h2>\n<p>The <strong>Konica Minolta CM-36dGV<\/strong> vertical color and gloss spectrophotometer is a stationary benchtop upright spectrophotometer. It integrates a d\/8 optical geometry along with a gloss sensor, enabling simultaneous measurement of color and gloss while maintaining backward data compatibility with the long-time best-selling KONICA MINOLTA CM-3600A series (when measuring in SCI\/LAV mode).<\/p>\n<p>Its superior measurement accuracy supports digitized quality control across global supply chains. The KONICA MINOLTA CM-36dGV spectrophotometer series is designed with a vertical, bottom-port configuration and an integrated gloss measurement module.<\/p>\n<p><a href=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-5.jpg\"><img decoding=\"async\" class=\"aligncenter wp-image-2131 size-full\" src=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-5.jpg\" alt=\"\" width=\"1300\" height=\"1300\" title=\"\" srcset=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-5.jpg 1300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-5-300x300.jpg 300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-5-1024x1024.jpg 1024w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-5-150x150.jpg 150w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-5-768x768.jpg 768w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-5-510x510.jpg 510w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-5-100x100.jpg 100w\" sizes=\"(max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<h2>Key Features of Konica Minolta CM-36dGV<\/h2>\n<ul data-start=\"0\" data-end=\"601\">\n<li data-start=\"0\" data-end=\"79\">\n<p data-start=\"2\" data-end=\"79\">Simultaneous color and gloss measurement with high Inter-Instrument Agreement (IIA).<\/p>\n<\/li>\n<li data-start=\"80\" data-end=\"164\">\n<p data-start=\"82\" data-end=\"164\">Colorimetric: $\\Delta E^*ab &lt; 0.12$ (LAV\/SCI; average of 12 BCRA Series II color tiles).<\/p>\n<\/li>\n<li data-start=\"165\" data-end=\"203\">\n<p data-start=\"167\" data-end=\"203\">Gloss: $\\pm0.2$ GU (MAV; 0 \u2013 10 GU).<\/p>\n<\/li>\n<li data-start=\"204\" data-end=\"258\">\n<p data-start=\"206\" data-end=\"258\">Wavelength Analysis &amp; Adjustment (WAA) function.<\/p>\n<\/li>\n<li data-start=\"259\" data-end=\"334\">\n<p data-start=\"261\" data-end=\"334\">Excellent Inter-Model Agreement (IMA) with the legacy CM-3600A series.<\/p>\n<\/li>\n<li data-start=\"335\" data-end=\"405\">\n<p data-start=\"337\" data-end=\"405\">Status panel displaying all device settings and operational conditions.<\/p>\n<\/li>\n<li data-start=\"406\" data-end=\"502\">\n<p data-start=\"408\" data-end=\"433\">4 different measurement areas (apertures):<\/p>\n<ul data-start=\"436\" data-end=\"502\">\n<li data-start=\"436\" data-end=\"452\">\n<p data-start=\"438\" data-end=\"452\">LAV \u00f825.4 mm<\/p>\n<\/li>\n<li data-start=\"455\" data-end=\"470\">\n<p data-start=\"457\" data-end=\"470\">LMAV \u00f816 mm<\/p>\n<\/li>\n<li data-start=\"473\" data-end=\"486\">\n<p data-start=\"475\" data-end=\"486\">MAV \u00f88 mm<\/p>\n<\/li>\n<li data-start=\"489\" data-end=\"502\">\n<p data-start=\"491\" data-end=\"502\">SAV \u00f84 mm<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"503\" data-end=\"526\">\n<p data-start=\"505\" data-end=\"526\">Sample preview viewfinder function.<\/p>\n<\/li>\n<li data-start=\"527\" data-end=\"601\">\n<p data-start=\"529\" data-end=\"601\">Vertical design optimizes handling for flexible sheet-like samples such as textiles, fabrics, and paper.<\/p>\n<\/li>\n<\/ul>\n<p><a href=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-1-1.jpg\"><img decoding=\"async\" class=\"aligncenter wp-image-2139 size-full\" src=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-1-1.jpg\" alt=\"\" width=\"1300\" height=\"1300\" title=\"\" srcset=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-1-1.jpg 1300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-1-1-300x300.jpg 300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-1-1-1024x1024.jpg 1024w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-1-1-150x150.jpg 150w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-1-1-768x768.jpg 768w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-1-1-510x510.jpg 510w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/06\/cm-36dgv-1-1-100x100.jpg 100w\" sizes=\"(max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<h2 id=\"mts-thong-so-ky-thuat-cua-konica-minolta-cm-36dgv\" class=\"ftwp-heading\">Technical Specifications of KONICA MINOLTA CM-36dGV<\/h2>\n<ul>\n<li>Color\n<ul>\n<li>Illumination\/Viewing system:\n<ul>\n<li>Reflectance:\n<ul>\n<li>di:8\u00b0, de:8\u00b0 (diffuse illumination, 8\u00b0 viewing angle), switchable SCI (Specular Component Included) \/ SCE (Specular Component Excluded)<\/li>\n<li>Complies with CIE No. 15, ISO 7724\/1, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 condition c standards<\/li>\n<\/ul>\n<\/li>\n<li>Transmittance:\n<ul>\n<li>di:0\u00b0, de:0\u00b0 (diffuse illumination, 0\u00b0 viewing angle)<\/li>\n<li>Complies with CIE No.15 condition g, ASTM E1164, DIN 5033 Teil 7, and JIS Z 8722 standards<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li>Integrating sphere size: \u00d8152 mm (6 inches)<\/li>\n<li>Detector: Dual 40-element silicon photodiode array<\/li>\n<li>Spectral separation device: Diffraction grating<\/li>\n<li>Wavelength range: 360 nm to 740 nm<\/li>\n<li>Wavelength pitch: 10 nm<\/li>\n<li>Half bandwidth: Approx. 10 nm<\/li>\n<li>Reflectance range:\n<ul>\n<li>0 to 200%<\/li>\n<li>Output resolution: 0.01%<\/li>\n<\/ul>\n<\/li>\n<li>Light source: 3 pulsed Xenon lamps (2 lamps equipped with UV-cut filters)<\/li>\n<li>Measurement\/Illumination area:\n<ul>\n<li>LAV: \u00d825.4 mm \/ \u00d830.0 mm<\/li>\n<li>LMAV: \u00d816.0 mm \/ \u00d820.0 mm<\/li>\n<li>MAV: \u00d88.0 mm \/ \u00d811.0 mm<\/li>\n<li>SAV: \u00d84.0 mm \/ \u00d87.0 mm<\/li>\n<li>Transmittance: \u00d817.0 mm \/ \u00d824.0 mm<\/li>\n<\/ul>\n<\/li>\n<li>Repeatability:\n<ul>\n<li>Colorimetric value: Standard deviation within $\\Delta E^*ab \\le 0.02$<\/li>\n<li>Spectral reflectance: Standard deviation within 0.1%<\/li>\n<li>(When a white calibration plate is measured 30 times at 10-second intervals after white calibration)<\/li>\n<\/ul>\n<\/li>\n<li>Inter-instrument agreement: $\\Delta E^*ab \\le 0.12$ (Based on the average of 12 BCRA Series II color tiles; LAV\/SCI; compared to values measured with the master body under Konica Minolta standard conditions)<\/li>\n<li>UV setting:\n<ul>\n<li>100% \/ 0% \/ Adjusted<\/li>\n<li>Instantaneous Numerical UV Adjustment without mechanical filter movement; includes 400 nm and 420 nm UV cutoff filters<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li>Gloss\n<ul>\n<li>Measurement angle: 60\u00b0<\/li>\n<li>Light source: White LED<\/li>\n<li>Detector: Silicon photodiode<\/li>\n<li>Measurement range:\n<ul>\n<li>0 to 200 GU<\/li>\n<li>Resolution: 0.01 GU<\/li>\n<\/ul>\n<\/li>\n<li>Measurement area:\n<ul>\n<li>MAV (for LAV\/LMAV\/MAV color apertures): Ellipse \u00d810.0 x 8.0 mm<\/li>\n<li>SAV (for SAV color aperture): \u00d83.0 mm<\/li>\n<\/ul>\n<\/li>\n<li>Repeatability:\n<ul>\n<li>0 to 10 GU: within 0.1 GU<\/li>\n<li>10 to 100 GU: within 0.2 GU<\/li>\n<li>100 to 200 GU: within 0.2%<\/li>\n<li>(When measured 30 times at 10-second intervals)<\/li>\n<\/ul>\n<\/li>\n<li>Inter-instrument agreement:\n<ul>\n<li>0 to 10 GU: \u00b1 0.2 GU<\/li>\n<li>10 to 100 GU: \u00b1 0.5 GU<\/li>\n<li>(MAV. Compared to values measured with the master body under Konica Minolta standard conditions)<\/li>\n<\/ul>\n<\/li>\n<li>Geometry: JIS Z 8741 (MAV), JIS K 5600, ISO 2813, ISO 7668 (MAV), ASTM D523-08, ASTM D2457-13, and DIN 67530<\/li>\n<\/ul>\n<\/li>\n<li>Measurement time of CM-36dGV:\n<ul>\n<li>Approx. 3.5 seconds (SCI + SCE measurement)<\/li>\n<li>Approx. 4.0 seconds (SCI + SCE + Gloss measurement)<\/li>\n<li>Approx. 2.5 seconds (Transmittance)<\/li>\n<li>Approx. 3.0 seconds (UV-cut\/UV-adjusted; SCI or SCE)<\/li>\n<\/ul>\n<\/li>\n<li>Minimum measurement interval:\n<ul>\n<li>Approx. 4.0 seconds (SCI + SCE measurement)<\/li>\n<li>Approx. 4.5 seconds (SCI + SCE + Gloss measurement)<\/li>\n<li>Approx. 3.0 seconds (Transmittance)<\/li>\n<li>Approx. 4.0 seconds (UV-cut\/UV-adjusted; SCI or SCE)<\/li>\n<\/ul>\n<\/li>\n<li>Sample preview function:\n<ul>\n<li>Utilizes internal camera<\/li>\n<li>(Images can be viewed\/captured using optional color software, such as SpectraMagic NX Version 3.2 or later)<\/li>\n<\/ul>\n<\/li>\n<li>Internal performance check: WAA (Wavelength Analysis &amp; Adjustment) technology<\/li>\n<li>Interface: USB 2.0<\/li>\n<li>Automatic target mask detection: Yes<\/li>\n<li>Power supply: Dedicated AC adapter<\/li>\n<li>Operating temperature\/humidity range: 13 to 33\u00b0C, relative humidity: 80% or less (at 35\u00b0C) non-condensing<\/li>\n<li>Storage temperature\/humidity range: 0 to 40\u00b0C, relative humidity: 80% or less (at 35\u00b0C) non-condensing<\/li>\n<li>Dimensions (W x H x D): Approx. 300 x 677 x 315 mm<\/li>\n<li>Weight of CM-36dGV: Approx. 14.0 kg<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Introduction to KONICA MINOLTA CM-36dGV Vertical Spectrophotometer The Konica Minolta CM-36dGV vertical color and gloss spectrophotometer is a stationary benchtop upright spectrophotometer. It integrates a d\/8 optical geometry along with a gloss sensor, enabling simultaneous measurement of color and gloss while maintaining backward data compatibility with the long-time best-selling KONICA MINOLTA CM-3600A series (when measuring<\/p>\n","protected":false},"featured_media":2136,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[108],"product_cat":[68],"product_tag":[1462,1463,1466,1465,1461,1464],"class_list":["post-2141","product","type-product","status-publish","has-post-thumbnail","product_brand-konica","product_cat-spectrophotometer-for-measuring-material-color","product_tag-konica-minolta-cm-36dgv","product_tag-laboratory-vertical-benchtop-colorimeter","product_tag-plastic-pellet-and-thin-film-optical-analyzer","product_tag-textile-and-paper-color-quality-control","product_tag-vertical-color-and-gloss-integrated-spectro","product_tag-vertical-d-8-sphere-spectrophotometer","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product\/2141","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/comments?post=2141"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/media\/2136"}],"wp:attachment":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/media?parent=2141"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_brand?post=2141"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_cat?post=2141"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_tag?post=2141"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}