{"id":2652,"date":"2026-07-03T09:25:12","date_gmt":"2026-07-03T09:25:12","guid":{"rendered":"https:\/\/maydomau.vn\/may-do-do-sang-konica-minolta-t-10a\/"},"modified":"2026-07-08T01:29:31","modified_gmt":"2026-07-08T01:29:31","slug":"konica-minolta-t-10a-illuminance-meter","status":"publish","type":"product","link":"https:\/\/maydomau.vn\/en\/san-pham\/konica-minolta-t-10a-illuminance-meter\/","title":{"rendered":"Konica Minolta T-10A Illuminance Meter"},"content":{"rendered":"<h2>Introduction to KONICA MINOLTA T-10A Illuminance Meter<\/h2>\n<p>The <strong>Konica Minolta T-10A<\/strong> illuminance meter is a professional light measurement device designed to accurately evaluate light intensity across diverse environments, ranging from industrial manufacturing, scientific research, and public facility lighting to occupational workplace inspections and cleanroom environments.<\/p>\n<p><a href=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-6022.jpg\"><img decoding=\"async\" class=\"aligncenter wp-image-3137 size-full\" src=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-6022.jpg\" alt=\"\" width=\"1300\" height=\"1300\" title=\"\" srcset=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-6022.jpg 1300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-6022-300x300.jpg 300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-6022-1024x1024.jpg 1024w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-6022-150x150.jpg 150w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-6022-768x768.jpg 768w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-6022-510x510.jpg 510w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-6022-100x100.jpg 100w\" sizes=\"(max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<h2 id=\"mts-tinh-nang-noi-bat-cua-konica-minolta-t-10a\" class=\"ftwp-heading\">Key Features of KONICA MINOLTA T-10A<\/h2>\n<ul data-start=\"497\" data-end=\"861\">\n<li data-start=\"497\" data-end=\"579\">\n<p data-start=\"499\" data-end=\"579\"><strong data-start=\"499\" data-end=\"528\">Accurately measures illuminance (lux)<\/strong> and features <strong data-start=\"532\" data-end=\"576\">integrated illuminance over time (lux\u00b7h)<\/strong>.<\/p>\n<\/li>\n<li data-start=\"580\" data-end=\"655\">\n<p data-start=\"582\" data-end=\"655\"><strong data-start=\"582\" data-end=\"603\">Detachable receptor head<\/strong>: <strong>Konica Minolta T-10A<\/strong> enables flexible measurement in tight or hard-to-reach inspection points.<\/p>\n<\/li>\n<li data-start=\"656\" data-end=\"754\">\n<p data-start=\"658\" data-end=\"692\"><strong data-start=\"658\" data-end=\"689\">Compliance with international standards<\/strong>:<\/p>\n<ul data-start=\"695\" data-end=\"754\">\n<li data-start=\"695\" data-end=\"727\">\n<p data-start=\"697\" data-end=\"727\">JIS C 1609-1:2006 (Class AA)<\/p>\n<\/li>\n<li data-start=\"730\" data-end=\"754\">\n<p data-start=\"732\" data-end=\"754\">DIN 5032-7 (Class B)<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"755\" data-end=\"861\">\n<p data-start=\"757\" data-end=\"861\"><strong data-start=\"757\" data-end=\"789\">Supports flicker frequency measurements<\/strong>, making it highly suitable for evaluating LED luminaires, fluorescent lamps, or PWM-driven light sources.<\/p>\n<\/li>\n<\/ul>\n<p><a href=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-1.jpg\"><img decoding=\"async\" class=\"aligncenter wp-image-2650 size-full\" src=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-1.jpg\" alt=\"\" width=\"1300\" height=\"1300\" title=\"\" srcset=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-1.jpg 1300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-1-300x300.jpg 300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-1-1024x1024.jpg 1024w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-1-150x150.jpg 150w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-1-768x768.jpg 768w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-1-510x510.jpg 510w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-1-100x100.jpg 100w\" sizes=\"(max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<h2 id=\"mts-ung-dung-cua-t-10a\" class=\"ftwp-heading\">Applications of T-10A<\/h2>\n<ul data-start=\"1327\" data-end=\"1634\">\n<li data-start=\"1327\" data-end=\"1487\">\n<p data-start=\"1329\" data-end=\"1378\">Testing and evaluating lighting systems within:<\/p>\n<ul data-start=\"1381\" data-end=\"1487\">\n<li data-start=\"1381\" data-end=\"1415\">\n<p data-start=\"1383\" data-end=\"1415\">Commercial offices, manufacturing plants, and cleanrooms<\/p>\n<\/li>\n<li data-start=\"1418\" data-end=\"1445\">\n<p data-start=\"1420\" data-end=\"1445\">Movie theaters and stages<\/p>\n<\/li>\n<li data-start=\"1448\" data-end=\"1487\">\n<p data-start=\"1450\" data-end=\"1487\">Research and laboratory environments<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"1488\" data-end=\"1551\">\n<p data-start=\"1490\" data-end=\"1551\">Measuring and ensuring compliance with occupational workplace safety lighting standards<\/p>\n<\/li>\n<li data-start=\"1552\" data-end=\"1634\">\n<p data-start=\"1554\" data-end=\"1634\">Inspecting light quality during the quality control process of electronic products, LCD panels, and LED components<\/p>\n<\/li>\n<\/ul>\n<p><a href=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01.jpg\"><img decoding=\"async\" class=\"aligncenter wp-image-2646 size-full\" src=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01.jpg\" alt=\"\" width=\"1300\" height=\"1300\" title=\"\" srcset=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01.jpg 1300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-300x300.jpg 300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-1024x1024.jpg 1024w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-150x150.jpg 150w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-768x768.jpg 768w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-510x510.jpg 510w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/07\/tc-01-100x100.jpg 100w\" sizes=\"(max-width: 1300px) 100vw, 1300px\" \/><\/a><\/p>\n<h2 id=\"mts-thong-so-ky-thuat-cua-t-10a\">Technical Specifications of T-10A<\/h2>\n<article dir=\"auto\" data-testid=\"conversation-turn-16\" data-scroll-anchor=\"true\">\n<div>\n<div tabindex=\"-1\">\n<div>\n<div>\n<div>\n<div dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"2e5b1a3a-2844-4422-9f55-c407dae8ba78\" data-message-model-slug=\"gpt-4o\">\n<div>\n<div>\n<p data-start=\"0\" data-end=\"118\">Type: Multi-functional digital illuminance meter with a detachable receptor head (supports multi-point measurements from 2 to 30 points)<\/p>\n<p data-start=\"120\" data-end=\"151\">Detector: Silicon photocell<\/p>\n<p data-start=\"153\" data-end=\"260\">Relative spectral response: Within 6% (f1\u00b4) of the CIE spectral luminous efficiency curve V(\u03bb)<\/p>\n<p data-start=\"262\" data-end=\"303\">Cosine response (f2): Within 3%<\/p>\n<p data-start=\"305\" data-end=\"388\">Measurement range: Auto-ranging (features 5 manual ranges when utilizing analog output)<\/p>\n<p data-start=\"390\" data-end=\"407\">Measurement functions:<\/p>\n<ul data-start=\"408\" data-end=\"558\">\n<li data-start=\"408\" data-end=\"424\">\n<p data-start=\"410\" data-end=\"424\">Illuminance (lux)<\/p>\n<\/li>\n<li data-start=\"425\" data-end=\"452\">\n<p data-start=\"427\" data-end=\"452\">Illuminance difference (lux)<\/p>\n<\/li>\n<li data-start=\"453\" data-end=\"473\">\n<p data-start=\"455\" data-end=\"473\">Illuminance ratio (%)<\/p>\n<\/li>\n<li data-start=\"474\" data-end=\"502\">\n<p data-start=\"476\" data-end=\"502\">Integrated illuminance (lux\u00b7h)<\/p>\n<\/li>\n<li data-start=\"503\" data-end=\"532\">\n<p data-start=\"505\" data-end=\"532\">Integration time (hours)<\/p>\n<\/li>\n<li data-start=\"533\" data-end=\"558\">\n<p data-start=\"535\" data-end=\"558\">Average illuminance (lux)<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"560\" data-end=\"575\">Measuring ranges:<\/p>\n<ul data-start=\"576\" data-end=\"736\">\n<li data-start=\"576\" data-end=\"633\">\n<p data-start=\"578\" data-end=\"633\">Illuminance: 0.01 to 299,900 lx; 0.001 to 29,990 fcd<\/p>\n<\/li>\n<li data-start=\"634\" data-end=\"736\">\n<p data-start=\"636\" data-end=\"736\">Integrated illuminance: 0.01 to 999,900 x 10\u00b3 lx\u00b7h; 0.001 to 99,990 x 10\u00b3 fcd\u00b7h \/ 0.001 to 9,999 hours<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"738\" data-end=\"779\">Linearity: \u00b12% \u00b11 digit of displayed value<\/p>\n<p data-start=\"781\" data-end=\"831\">Temperature \/ humidity drift: Within \u00b13%<\/p>\n<p data-start=\"833\" data-end=\"860\">Digital output: USB<\/p>\n<p data-start=\"862\" data-end=\"959\">Analog output: 1 mV\/digit, 3 V maximum; Output impedance: 10 k\u03a9; 90% response time: 28 ms<\/p>\n<p data-start=\"961\" data-end=\"1044\">Display: 3- or 4-digit backlit LCD screen (automatically illuminated)<\/p>\n<p data-start=\"1046\" data-end=\"1187\">Power supply: 2 x AA batteries \/ AC Adapter AC-A308 (optional; handles 1 to 10 receptor heads) or AC-A311 (optional; handles 1 to 30 receptor heads)<\/p>\n<p data-start=\"1189\" data-end=\"1275\" data-is-last-node=\"\" data-is-only-node=\"\">Battery life: 72 hours or more (when utilizing alkaline batteries) under continuous measurement conditions<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n","protected":false},"excerpt":{"rendered":"<p>Introduction to KONICA MINOLTA T-10A Illuminance Meter The Konica Minolta T-10A illuminance meter is a professional light measurement device designed to accurately evaluate light intensity across diverse environments, ranging from industrial manufacturing, scientific research, and public facility lighting to occupational workplace inspections and cleanroom environments. Key Features of KONICA MINOLTA T-10A Accurately measures illuminance (lux)<\/p>\n","protected":false},"featured_media":3137,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[108],"product_cat":[69],"product_tag":[1776,1777,1780,1778,1779],"class_list":["post-2652","product","type-product","status-publish","has-post-thumbnail","product_brand-konica","product_cat-spectrophotometer","product_tag-illuminance-lux-meter","product_tag-konica-minolta-t-10a","product_tag-led-lighting-system-calibration","product_tag-light-intensity-tester","product_tag-lux-and-foot-candle-spectrometer","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product\/2652","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/comments?post=2652"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/media\/3137"}],"wp:attachment":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/media?parent=2652"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_brand?post=2652"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_cat?post=2652"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_tag?post=2652"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}