{"id":4497,"date":"2026-08-12T15:51:23","date_gmt":"2026-08-12T15:51:23","guid":{"rendered":"https:\/\/maydomau.vn\/san-pham\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm\/"},"modified":"2026-10-06T16:26:02","modified_gmt":"2026-10-06T16:26:02","slug":"lisun-pcr-xm-photometric-calibration-system","status":"publish","type":"product","link":"https:\/\/maydomau.vn\/en\/product\/lisun-pcr-xm-photometric-calibration-system\/","title":{"rendered":"Lisun PCR-XM Photometric Calibration System"},"content":{"rendered":"<h2><strong>Lisun PCR-XM Photometric Calibration System<\/strong><\/h2>\n<p><strong>The Lisun PCR-XM Photometric Calibration System<\/strong> is an optimal industrial solution designed to perform calibration and check the accuracy of spectrophotometers, illuminance meters, luminance meters, and light source analysis systems. The device operates based on advanced optical standardization methods, helping to thoroughly calibrate without distorting the original metrological standards of the product.<\/p>\n<p><a href=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm.png\"><img decoding=\"async\" class=\"wp-image-4493 size-full aligncenter\" src=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm.png\" alt=\"\" width=\"750\" height=\"750\" title=\"\" srcset=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm.png?v=1789712944 750w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-300x300.png?v=1789712944 300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-150x150.png?v=1789712944 150w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-510x510.png?v=1789712944 510w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-100x100.png?v=1789712944 100w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/a><\/p>\n<h2><strong>Technical Specifications:<\/strong><\/h2>\n<p>1. 8-meter optical guide rail<\/p>\n<p>2. Standard intensity light source with reflector (400W) (with CNAS calibration certificate) 2 sets<\/p>\n<p>3. LS2050 digital power meter (0.2 AC \/ DC class, with CNAS calibration certificate) 1 set<\/p>\n<p>4. DC16012 Programmable Switching DC Power Supply (with CNAS calibration certificate) 1 set<\/p>\n<p>5. F4 standard white board (with CNAS calibration certificate) 1 set<\/p>\n<p>6. Standard intensity light source with reflector (150W) (with CNAS calibration certificate) 2 sets<\/p>\n<p>7. Transmissive standard color filters (One set each of red, orange, yellow, green, and blue filter plates) (with CNAS calibration certificate) 1 set<\/p>\n<p>8. Rail fixture device (3 baffle plates, 1 probe fixture, 1 standard lamp fixture) 1 set<\/p>\n<p><strong>Note:<\/strong> The length of the optical rail can be customized.<\/p>\n<h2><strong>Outstanding Features<\/strong><\/h2>\n<p><a href=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-1.png\"><img decoding=\"async\" class=\"wp-image-4491 size-full aligncenter\" src=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-1.png\" alt=\"\" width=\"750\" height=\"750\" title=\"\" srcset=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-1.png?v=1789712941 750w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-1-300x300.png?v=1789712941 300w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-1-150x150.png?v=1789712941 150w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-1-510x510.png?v=1789712941 510w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-1-100x100.png?v=1789712941 100w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/a><\/p>\n<p><strong>Comprehensive standard optical system:<\/strong> The device is equipped with extremely high-precision standard light sources and optical systems, ensuring the provision of absolute accurate wavelength and illuminance intensity information throughout the calibration process.<\/p>\n<p><strong>Powerful measurement and calibration performance:<\/strong> Applying specialized analytical software technology, the system has the ability to automatically compare, calculate errors, and adjust measuring devices, achieving extremely high efficiency in standardizing optical parameters before putting devices into practical operation.<\/p>\n<p><strong>Intelligent operation and connection system:<\/strong><\/p>\n<ul>\n<li>Automatic control interface: Helps coordinate the measurement and calibration process smoothly, minimizing errors caused by manual operations.<\/li>\n<li>Combined data processing system: Integrates specialized software supporting report generation, calibration data storage, and easy tracking of equipment inspection history.<\/li>\n<\/ul>\n<p><strong>Manufacturing materials and durable structure:<\/strong> The entire optical frame and electronic components use high-grade anti-interference materials, helping to maintain spectral stability, protect equipment safety, and ensure long-term accuracy.<\/p>\n<p><strong>Advanced safety operation mechanism:<\/strong> The system is designed according to modern optical laboratory standards, integrating circuit protection and error warning features, ensuring stable operation in inspection centers and continuous production factories.<\/p>\n<h2><strong>Practical Applications<\/strong><\/h2>\n<p><a href=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm.jpg\"><img decoding=\"async\" class=\"wp-image-4495 size-full aligncenter\" src=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm.jpg\" alt=\"\" width=\"750\" height=\"750\" title=\"\" srcset=\"https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm.jpg?v=1787977438 750w, https:\/\/maydomau.vn\/wp-content\/uploads\/2026\/08\/he-thong-hieu-chuan-do-quang-lisun-pcr-xm-510x510.jpg?v=1787977438 510w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/a><\/p>\n<p>In addition to its main function of calibrating optical and color measuring devices, the Lisun PCR-XM is also widely applied in many other industries due to its high flexibility:<\/p>\n<ul>\n<li><strong>Lighting &amp; LED Industry:<\/strong> Calibrating measurement devices used in production lines of light bulbs, LEDs, street lights, and industrial lighting equipment.<\/li>\n<li><strong>Laboratories &amp; Metrology Institutes:<\/strong> Serving inspection work, optical research, and periodic calibration of national or facility-level spectral measurement standards.<\/li>\n<li><strong>Other Industrial Manufacturing:<\/strong> Testing and standardizing color measurement systems and optical sensors in display manufacturing, electronic components, and optoelectronic industries.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Lisun PCR-XM Photometric Calibration System The Lisun PCR-XM Photometric Calibration System is an optimal industrial solution designed to perform calibration and check the accuracy of spectrophotometers, illuminance meters, luminance meters, and light source analysis systems. The device operates based on advanced optical standardization methods, helping to thoroughly calibrate without distorting the original metrological standards of<\/p>\n","protected":false},"featured_media":4494,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[107],"product_cat":[3095],"product_tag":[3456,3454,3452,3453,3455],"class_list":["post-4497","product","type-product","status-publish","has-post-thumbnail","product_brand-lisun","product_cat-transmitted-light-meter","product_tag-lighting-accuracy-establishment","product_tag-luminous-parameter-correlation","product_tag-metrology-standard-assurance","product_tag-spectral-error-evaluation","product_tag-standard-light-source-control","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product\/4497","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/comments?post=4497"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/media\/4494"}],"wp:attachment":[{"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/media?parent=4497"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_brand?post=4497"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_cat?post=4497"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/maydomau.vn\/en\/wp-json\/wp\/v2\/product_tag?post=4497"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}